The optimum solution for lift applications. iV5L series provide the high precision Vector Control & precise Speed Control which guarantees a superb control stability in the Lift, Crane & Continuous Line systems.
SIN/COS+Endat
Option Card for SIN/COS and EnDat encoder· Selectable Endat & Sin/COS Option
· Max. 3,600rpm speed
· Enhanced Comfortable feeling in Car
- Compatibility with Heidenhain Encorder
- ECN413, ECN1313, ERN487, ERN1387
SIN/COS
Option Card for SIN/COS encoder· Sin/COS Option
· Max. 130rpm(at 2048ppr) to 550rpm(at 512ppr) speed
· Enhanced Comfortable feeling in Car
- Compatibility with Heidenhain Encorder
- ECN413, ECN1313, ERN487, ERN1387
Elevator I/O
Embedded with lift sequence program· Position sensor/Safety switch input
· Car position output
· E/L position and sequence control
· MC/Brake operation signal output
· E/L exclusive connector
► Integrated Software for both IM/PM Control
· Selectable IM/PM control with embedded keypad
- Induction Motor : V/F, Slip Compensation, Sensored Vector
- Permanent Magnet Motor : Sensored Vector
► Built-in Safe Torque Off(STO)
· Disconnects the power base on input signal through redundant satefy terminal in case of emergency
- Safety function satisfies EN61508, SIL2(EN13849-1)
► Auto Torque Boost
· Open loop control performance secured
► Anti-rollback
· Prevents roll back through starting torque compensation by encoder position control when Lift brake opens
► ALLS(Automatic Light Load Search)
· Function to allow Lift to run safely in direction with less load in Battery operation(in emergency)
► Anti Hunting Regulation
· Constains current hunting(Current distortion or Oscillation) casused by mechanical resonance under V/F control
► Battery Operation
· Emergency motor operation using externally installed battery power when main power is not supplied due to power failure(Speed and battery input voltage could be set in battery operation)
► Trip/Warning function
· Able to monitor fault by warning and trip setting - Trip : Fan, fault, Battery signal loss during the battery operation, A3 fault, LV2 fault, Satety A/B fault, SINCOS input connection check, Data Clock settings for Endat option board
- Warning : Fan alarm
- Endat encoder fault detection
3-Phase 400V(5.5~22kW)
LSLV ㅁㅁㅁ iV5L-4CNNN | 055 | 075 | 110 | 150 | 185 | 220 | ||
---|---|---|---|---|---|---|---|---|
Rating |
HP | 7.5 | 10 | 15 | 20 | 25 | 30 | |
kW | 5.4 | 7.5 | 11 | 15 | 18.5 | 22 | ||
Output Rating |
Capacity [kVA] |
9.1 | 12.2 | 18.3 | 22.9 | 29.0 | 34.3 | |
Rated Current [A] |
12 | 16 | 24 | 30 | 39 | 45 | ||
Speed |
0~3600 rpm | |||||||
Voltage [V] |
0~380 V (480V) | |||||||
Input Rating |
Voltage [V] | 3-phase 380~480VAC (-10% ~ +10%) | ||||||
Frequency [Hz] | 50~60Hz ( ±5%) | |||||||
Weight (kg(lbs)) |
7.7 |
7.7 |
13.7 (30.2) |
13.7 (30.2) |
20.3 (44.7) |
20.3 (44.7) |