Visit us at Biel - Project Lebanon 26 - 29 June 2018

iV5L 5.5~22kW 3-Phase 380~480V PM/IM Lift Drive

The optimum solution for lift applications. iV5L series provide the high precision Vector Control & precise Speed Control which guarantees a superb control stability in the Lift, Crane & Continuous Line systems.


Email us for Price

SIN/COS+Endat
Option Card for SIN/COS and EnDat encoder· Selectable Endat & Sin/COS Option
· Max. 3,600rpm speed
· Enhanced Comfortable feeling in Car
   - Compatibility with Heidenhain Encorder
   - ECN413, ECN1313, ERN487, ERN1387

SIN/COS
Option Card for SIN/COS encoder· Sin/COS Option
· Max. 130rpm(at 2048ppr) to 550rpm(at 512ppr) speed
· Enhanced Comfortable feeling in Car
   - Compatibility with Heidenhain Encorder
   - ECN413, ECN1313, ERN487, ERN1387

Elevator I/O
Embedded with lift sequence program· Position sensor/Safety switch input
· Car position output
· E/L position and sequence control
· MC/Brake operation signal output
· E/L exclusive connector

 

► Integrated Software for both IM/PM Control
 ·  Selectable IM/PM control with embedded keypad
   - Induction Motor : V/F, Slip Compensation, Sensored Vector
   - Permanent Magnet Motor : Sensored Vector 

► Built-in Safe Torque Off(STO)
 ·  Disconnects the power base on input signal through redundant satefy terminal in case of emergency
   - Safety function satisfies EN61508, SIL2(EN13849-1) 

► Auto Torque Boost
 ·  Open loop control performance secured 

► Anti-rollback
 ·  Prevents roll back through starting torque compensation by encoder position control when Lift brake opens 

► ALLS(Automatic Light Load Search)
 ·  Function to allow Lift to run safely in direction with less load in Battery operation(in emergency) 

► Anti Hunting Regulation
 ·  Constains current hunting(Current distortion or Oscillation) casused by mechanical resonance under V/F control 

► Battery Operation
 ·  Emergency motor operation using externally installed battery power when main power is not supplied due to power failure(Speed and battery input voltage could be set in battery operation) 

► Trip/Warning function
 ·  Able to monitor fault by warning and trip setting    - Trip : Fan, fault, Battery signal loss during the battery operation, A3 fault, LV2 fault, Satety A/B fault,     SINCOS input connection check, Data Clock settings for Endat option board
   - Warning : Fan alarm
   - Endat encoder fault detection 

 

3-Phase 400V(5.5~22kW)

LSLV ㅁㅁㅁ iV5L-4CNNN 055 075 110 150 185 220

 


Motor

Rating

HP 7.5 10 15 20 25 30
kW 5.4 7.5 11 15 18.5 22


 

Output

Rating

Capacity

[kVA]

9.1 12.2 18.3 22.9 29.0 34.3

Rated Current

[A]

12 16 24 30 39 45

Speed

0~3600 rpm

Voltage [V]

0~380 V (480V)

 

Input

Rating

Voltage [V] 3-phase 380~480VAC (-10% ~ +10%)
Frequency [Hz] 50~60Hz ( ±5%)

Weight (kg(lbs))

7.7
(16.9)

7.7
(16.9)

13.7
(30.2)
13.7
(30.2)
20.3
(44.7)
20.3
(44.7)
Sign Up For Our Newsletter